GeneRotex 24 Nucleic Acid Extractor
Tianlong GeneRotex 24 nucleic acid extractor is designed with our innovative rotary mixing technology (RMT), which can reduce aerosol generated during the purification process, minimize the risk of false positives caused by cross-contamination, and ensure the accuracy of experiment results. Compatible with Tianlong specialized large volume nucleic acid extraction kits, GeneRotex 24 can greatly improve detection sensitivity and extraction eficiency. The large sample volume workflow is suitable for more complicated downstream applications.
-
-
01
Workflow for extraction from large volume samples: The GeneRotex 24 is compatible with specialized large volume nucleic acid extraction kits. Up to 15 ml processing volume and 5 ml sample volume make pathogen detection sensitivity easier than before, Your extraction efficiency can be improved greatly.
Independent consumables design: The specialized single reaction tube design allows for the independent extraction of a single sample. This design ensures the sample processing process remains independent, preventing cross-contamination and reagent waste. -
02
Innovative rotary mixing technology: Based on Tianlong's innovative rotary mixing technology(RMT), GeneRotex 24 can reduce aerosol generated during the experiment and minimize the risk of false positives caused by cross-contamination while being super quiet during operation.
Negative pressure system with HEPA filtration: The negative pressure ventilation design with replaceable HEPA filtration can ensure the exhausted air with no biological hazards.
High purification and reliable results: Less than 1% residual amount of magnetic beads increase confidence in your experiment result.
Model | GeneRotex 24 |
Throughput | 1-24 |
Reaction Volume | 50-15000μL |
Sample Volume | 5000μl |
Compatible Consumables | Specialized 15mL single reaction tube! specialized stirring sleeve |
Rotational Speed | ≤3000rpm |
Heating Temperature | Lysis heating: room temperature to 120℃ Elution heating: room temperature to 120℃ |
Mixing Method | Rotary mixing |
Operation Mode | 7-inch full-color LCD touch screen operation |
Program Storage | Up to 1000 programs can be storaged |
Protocol Management | Flexible to create, edit and delete protocols |
Automatic Control | Motor-driven automatic opening and closing of the experiment cabinet |
Magnetic Bead Residue | ≤1% |
Power Failure Protection | Choose freely whether or not to continue the experiment when the power is on again after cutting off |
Contamination Control | Negative pressure; HEPA exhaust filter module; Built-in UV disinfection module |
Connection Port Type | USB port |
Weight | 45kg (net) |
Instrument Dimensions | 490mm(L) x540mm(w)x480mm (H) |
Power Supply and Power Consumption | AC100V-240V,50/60HZ:600VA |
Inter-well Extraction Difference | CV≤2% |
GeneRotex 24 | |
---|---|
Throughput | 1-24 |
Reaction Volume | 50-15000μL |
Sample Volume | 5000μl |
Compatible Consumables | Specialized 15mL single reaction tube! specialized stirring sleeve |
Rotational Speed | ≤3000rpm |
Heating Temperature | Lysis heating: room temperature to 120℃ Elution heating: room temperature to 120℃ |
Mixing Method | Rotary mixing |
Operation Mode | 7-inch full-color LCD touch screen operation |
Program Storage | Up to 1000 programs can be storaged |
Protocol Management | Flexible to create, edit and delete protocols |
Automatic Control | Motor-driven automatic opening and closing of the experiment cabinet |
Magnetic Bead Residue | ≤1% |
Power Failure Protection | Choose freely whether or not to continue the experiment when the power is on again after cutting off |
Contamination Control | Negative pressure; HEPA exhaust filter module; Built-in UV disinfection module |
Connection Port Type | USB port |
Weight | 45kg (net) |
Instrument Dimensions | 490mm(L) x540mm(w)x480mm (H) |
Power Supply and Power Consumption | AC100V-240V,50/60HZ:600VA |
Inter-well Extraction Difference | CV≤2% |
Contact us