Human Immunodeficiency Virus 1(HIV-1)Nucleic Acid Detection Kit
Tianlong Human Immunodefciency Virus 1 (HIV-1) Nucleic Acid Detection Kit is used for the quantitative detectior of human immunodeficiency virus nucleic acid type 1 (HIV-1 RNA) in human serum or plasma samples. It is intended for use in conjunction with clinical presentation and other laboratory markers of disease progress for the clinical management of HIV-1 infected patients. The test can be used to assess patient prognosis by measuring the baseline HIV-1 RNA level or to monitor the effects of antiretroviral therapy by measuring changes in serum or plasma HIV-1 RNA levels during antiretroviral treatment. The kit is not intended for use as a screenina test for the presence of HIV-1 in blood or blood products or as a diagnostictest to confirm the presence of HIV-1 infection.
-
Product Name | Human Immunodeficiency Virus 1(HIV-1)Nucleic Acid Detection Kit (RT-PCR Method) | Human Immunodeficiency Virus 1(HIV-1)Nucleic Acid Detection Kit (RT-PCR Method) |
Cat.No | P354H | P908H |
Specification | 24T/kit | 48T/kit |
Specimen | human serum or plasma samples | human serum or plasma samples |
Linear Range | |r|≥0.980 | |r|≥0.980 |
Sensitivity | Lower limit of detection is 20 IU/mL. limit of quantitation is 40 IU/ml | Lower limit of detection is 20 IU/mL. limit of quantitation is 40 IU/ml |
Precision | CV≤5% | CV≤5% |
Storage & Validity | -25°C~-15°C for 12 months | -25°C~-15°C for 12 months |
Applicable Equipment | Instruments with 4 fluorescence channels such as Tianlong Gentier Real-time PCR systems, ABI7500, ABI QuantStudioTM 5、Bio-Rad CFX96 | Instruments with 4 fluorescence channels such as Tianlong Gentier Real-time PCR systems, ABI7500, ABI QuantStudioTM 5、Bio-Rad CFX96 |
Human Immunodeficiency Virus 1(HIV-1)Nucleic Acid Detection Kit (RT-PCR Method) | |
---|---|
Cat.No | P354H |
Specification | 24T/kit |
Specimen | human serum or plasma samples |
Linear Range | |r|≥0.980 |
Sensitivity | Lower limit of detection is 20IU/mL. limit of quantitation is 40IU/ml |
Precision | CV≤5% |
Storage & Validity | -25°C~-15°C for 12 months |
Applicable Equipment | Instruments with 4 fluorescence channels such as Tianlong Gentier Real-time PCR systems, ABI7500, ABI QuantStudioTM 5、Bio-Rad CFX96 |
Human Immunodeficiency Virus 1(HIV-1)Nucleic Acid Detection Kit (RT-PCR Method) | |
---|---|
Cat.No | P908H |
Specification | 48T/kit |
Specimen | human serum or plasma samples |
Linear Range | |r|≥0.980 |
Sensitivity | Lower limit of detection is 20IU/mL. limit of quantitation is 40IU/ml |
Precision | CV≤5% |
Storage & Validity | -25°C~-15°C for 12 months |
Applicable Equipment | Instruments with 4 fluorescence channels such as Tianlong Gentier Real-time PCR systems, ABI7500, ABI QuantStudioTM 5、Bio-Rad CFX96 |