-
-
Human Influenza Virus B (Yamagata& Victoria) and A (H1&H3) Nucleic Acid Multiplex Detection Kit
Influenza virus infection can cause headache, fever, body ache, nasal congestion, sore throat, and other symptoms Influenza viruses include type A, B, and C, with type A being the most likely to cause epidemics, followed by type B and type C rarely causing epidemics. Influenza A virus can be divided into 16 H subtypes (H1H16) and 9 N subtypes (N1N9). Influenza B virus is not classified, but there are mainly two lineages -Yamagata (Y) and Victoria (V). At present, the main human infections are the H1, H3 subtypes of influenza A viruses and the Victoria and Yamagata strains of influenza B viruses
Tianlong Human Influenza Virus B (Yamagata&Victoria) and A(H1&H3)Nucleic Acid Multiplex Detection Kit is intended for the qualitative detection of Influenza virus B(Yamagata&Victoria) and A (H1&H3)RNA by Real-time RT-PCR method.lt is suitable for people with influenza virus symptoms or those who have been in close contact with influenza patients.
-
Product Name | Human Influenza Virus B (Yamagata&Victoria) and A(H1&H3) Nucleic Acid Multiplex Detection Kit (Fluorescence PCR Method) | Human Influenza Virus B (Yamagata&Victoria) and A(H1&H3) Nucleic Acid Multiplex Detection Kit (Fluorescence PCR Method) |
Cat.No | P255H | P655H |
Specification | 25T/Kit | 50T/Kit |
Specimen | Oropharyngeal swabs, nasopharyngeal swab | Oropharyngeal swabs, nasopharyngeal swab |
Sensitivity | 500 copies/mL | 500 copies/mL |
Precision | ≤5.0% | ≤5.0% |
Storage & Validity | -25℃~-15℃ for 12 months | -25℃~-15℃ for 12 months |
Applicable Equipment | Instruments with FAM,VIC (HEX) ROX (Texas Red), Cy5 chanels such as Applied BiosystemTM 7500 Real-Time PCR systems and Tianlong Gentier Real-time PCR systems | Instruments with FAM,VIC (HEX) ROX (Texas Red), Cy5 channels such as Applied BiosystemTM 7500 Real-Time PCR systems and Tianlong Gentier Real-time PCR system |
Certificate | CE marked | CE marked |
Human Influenza Virus B (Yamagata&Victoria) and A(H1&H3) Nucleic Acid Multiplex Detection Kit (Fluorescence PCR Method) | |
---|---|
Cat.No | P255H |
Specification | 25T/Kit |
Specimen | Oropharyngeal swabs, nasopharyngeal swab |
Sensitivity | 500 copies/mL |
Precision | ≤5.0% |
Storage & Validity | -25℃~-15℃ for 12 months |
Applicable Equipment | Instruments with FAM,VIC (HEX) ROX (Texas Red), Cy5 channels such as Applied BiosystemTM 7500 Real-Time PCR systems and Tianlong Gentier Real-time PCR system |
Certificate | CE marked |
Human Influenza Virus B (Yamagata&Victoria) and A(H1&H3) Nucleic Acid Multiplex Detection Kit (Fluorescence PCR Method) | |
---|---|
Cat.No | P655H |
Specification | 50T/Kit |
Specimen | Oropharyngeal swabs, nasopharyngeal swab |
Sensitivity | 500 copies/mL |
Precision | ≤5.0% |
Storage & Validity | -25℃~-15℃ for 12 months |
Applicable Equipment | Instruments with FAM,VIC (HEX) ROX (Texas Red), Cy5 channels such as Applied BiosystemTM 7500 Real-Time PCR systems and Tianlong Gentier Real-time PCR system |
Certificate | CE marked |
Contact us